- PID
- 3088380
Breath Alcohol Tester Iblow 10
High-quality, professional use to check person’s alcohol concentration quickly & accurately.
12 people can be measured per minute.
Test results are displayed in numbers and can also indicate 3 levels (zero-low-high).
- Certification
-
- Award
-
- Shipping
-
- Lead Time14 ~ 30days
- Modes of Transport CFR,CIF,EXW
- Payment
-
140+ Global Payments, trusted and secure payment provided by PayVerse.
Learn More
- Quantity
- MOQ : 100 Pieces
Detailed Description
With new Fuel Cell Sensor Technology of Sentech Korea, iblow 10 is designed to high-quality professional use to check person’s
alcohol concentration quickly & accurately
With iblow10, the alcohol levels of 12 people can be measured per minute and the results are displayed in numerics
and can also indicate zero, low, and high levels.
The device has manual sampling function so it is possible to check alcohol level of specific or random subject.
The blow cap is easily replaced for hygienic use, and the built-in magnets make it attachable to vehicles when police conducts roadside tests, preventing damage to the equipment. The LED lighting can also be used in various ways at night.
The user can also adjust the settings directly or connect it to PC software for more detailed settings. The alarm function also indicates the calibration warning and grace period of calibration warning, making it much more convenient.
Specification
Sensor Type: Suracell™ sensor (Fuel Cell sensor)
Battery: AA Size Alkaline Battery 6EA
Weight: 380g (Including batteries)
Size (mm): 276(Height) X 44.5(Width) X 44.5(Thickness)
Test result: LED Alert (Zero: Green / Low: Red / High: Blinking Red)
FND display (0.00/Lo/Hi or Numerical result)
(Display “HI” in Numerical result mode means more than 1.00 g/l of BAC)
Buzzer alarm: Zero : 1 Beep sound / Low : Repeating short Beep sound
High : Long Beep sound
Warming up time: Within 10 seconds
Time for analysis: Within 2 seconds (at 0.00 BAC)
Maximum test: 12 times / 1 minute
Working temperature: -5°C ~ 55°C (Optional -10°C ~ 55°C)
Storage temperature: -10°C ~ 60°C
Mouthpiece: Blow cap (Replaceable & washable passive cone type)
Auto power OFF Adjustable: 30 to 900 seconds
Duration time for display Adjustable: 1 to 9 seconds
Calibration period: Every 5,000 tests or 12 months whichever comes first
(Factory Default) *Changeable by Web-server software
Additional Function: Built-in Magnet
Reminder for calibration & Grace period
Calibration protection by Web-server connecting
Manual LED lighting: White, Red blinking, Red, Red & blue