High Level Disinfectant Opidex OPA Solution
Request For Quotation
SUNGKWANG PHARM's OPIDEX OPA SOLUTION is a high-level disinfectant for a broad spectrum of medical instruments, endoscopic instruments and devices.
- Award
-
- Shipping
-
- Modes of Transport FOB
- Payment
-
140+ Global Payments, trusted and secure payment provided by PayVerse.
Learn More
- Quantity
- MOQ : 1,440 Pieces
Detailed Description
Sungkwang pharm's OPIDEX OPA SOLUTION is a high-level disinfectant for broad spectrum of medical instrumnets, endoscopic instruments and devices.
| Features
| |
| Quick Disinfection | Only takes 5 minutes for complete disinfection (At room temperature, against tubercle bacillus) |
| Safeguards devices | Neutral disinfectant; does not damage devices |
| Safeguards users | Minimal odor; does not irritate against the users |
| Cost efficient | Long lifecycle for maximum utilization |
| Easy-to-use | Does not require activators; Can be used without dilution |
| Safe and effective | Thoroughly tested and stability |
| Drug Information
| |
| Products | OPIDEX OPA SOLUTION |
| Ingredients | Per 100ml |
| Ortho-phthalaldehyde - 0.55g | |
| Description | Transparent light blue liquid |
| Indications and Uses | Chemical Sterilization and Disinfection for |
| -Medical instruments or devices highly contaminated by microbes or organic matters or applied directly to the subcutaneous tissue or mucus layers | |
| -Medical instruments or devices suspected to be contaminated by type B hepatitis virus | |
| Applicable medical instruments and devices | |
| -Surgical instruments and devices including endoscopes, lens-installed devices, anesthesia apparatus, ventilators, hemodialyzers, mess, or catheters; obstetrics and urological instruments and devices dental instruments, devices, and aid tools; thermometers and syringes, or other instruments and devices made of plastics or rubber that are not applicable for heat sterilization | |
| Administration & Dosage | 1. Indications-Use undiluted solution directly onto the instruments and devices |
| 2. Administration | |
| 1)Sink the instruments or devices into the solution. Make sure the ridges, holes, or cavities of the instrument are in full contact with the solution. | |
| 2)the instruments or devices for more than 5 minutes. | |
| 3)After sinking, eliminate the remaining attachments from the instruments and wash them completely with sterile distilled water. When tap water is used in washing, wash the instruments again with alcohol, and dry them with pressurized dry air. | |
| Make sure the perforations on the instrument are completely clean. | |
| Storage | In the airtight container, at the temperature of 15~30°C |
| Packaging Units | 1L, 4L |
| Life Cycle | 24 months(After opening, for 75days(unused), or 14 days(used) |